Sign In | Join Free | My burrillandco.com
Home > Drinking Water RO System >

6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant

    Buy cheap 6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant from wholesalers
     
    Buy cheap 6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant from wholesalers
    • Buy cheap 6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant from wholesalers

    6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant

    Ask Lasest Price
    Brand Name : Jufu
    Model Number : JFRO-6000L
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability :
    Delivery Time : 2-4 weeks
    • Product Details
    • Company Profile

    6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant

    6TPH Automatic Control Reverse Osmosis Drinking Water Making Plant

    Advanced drinking water ro system - reverse osmosis membrane (RO):

    The pore size of the reverse osmosis membrane is the smallest, below 2-3 nm. Except for water molecules, all other impurity particles (including ions) cannot pass through the reverse osmosis membrane, so the water separated by the reverse osmosis membrane is pure water. Reverse osmosis technology has been widely used in seawater desalination, brackish water desalination, and preparation of high-purity water for industrial feed water (electronic industrial water, boiler feed water, etc.). The core technology of drinking pure water and high-quality direct drinking water that has developed rapidly in recent years is reverse osmosis.

    Technical specifications of Drinking Water RO System


    ModelJFRO-6000L
    Host Size3000x800x1600mm (can be customized)
    Power5.5KW
    Power Supply220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
    Operating Pressure0.8-1.2MPa
    Recovery Rate60%
    Designed Water Inlet10000L/h
    Outlet Flow6000L/h
    Desalination Rate≥99.5%
    RO FrameSUS304
    Membrane Size8040
    Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
    Number of Membranes6
    Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
    High Pressure PumpCNP/NYP/GRUNDFOS (Optional)
    Tank MaterialSS/FRP(Optional)
    Control ValveManual/Automatic
    Control Valve BrandFLECK/RUNXIN
    Membrane HousingFRP
    Number of Membrane housing3
    Pipe MaterialU-PVC/ Stainless steel (Optional)



























    Drinking Water RO System workflow:

    raw water - raw water tank - raw water booster pump - quartz sand filter - activated carbon filter - scale inhibitor dosing equipment - precision filter - first-stage high pressure pump - first-stage reverse osmosis Host - intermediate water tank - secondary high pressure pump - secondary reverse osmosis host - disinfection system - production water.


    Drinking water reverse osmosis system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

    1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.
    2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.
    3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.
    4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.
    5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.












    FAQ:

    1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

    Model 4040 is designed by 0.25m3/h

    Model 8040 is designed by 1-1.2m3/h

    2. What is the material of mechanical filter?

    Carbon steel, stainless steel, fiberglass

    3. what are the multi-way control valves?

    Manual control valve, automatic control valve

    Multi - way control valve is divided into: filter valve and softening valve

    Automatic control valve is divided into: time type and flow type.

    Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

    Quality 6TPH Automatic Reverse Osmosis Drinking Water System Drinking Water Making Plant for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jufu Water Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)